Lita Hydrogen Dual Bottle

¥64,900
¥-5,900 Tax-free
59,000
Free Shipping
#Aging Care #Beauty #Fast Delivery #Made in Japan #Maintaining Good Health #Premium #When Tired
Company:  Ichiban, Inc.
Brand:  WCJ






Life with hydrogen water





When you wake up in the morning and before you go to bed at night. For bath time or after taking a bath. during sports and meals. Getting ready, on the go, at work ——A quick and easy way to replenish hydrogen anytime, anywhere. Change your usual water to hydrogen water and make your body beautiful from inside.








■Dual-wielding! Excellent dual specification





Comes with a special inhalation kit that can be set in the hydrogen bottle body and can take in hydrogen from breathing. "Drinking" hydrogen water, "breathing" hydrogen gas, hydrogen replenishment that suits your lifestyle will come true.










■The habit of taking in high-quality hydrogen





It is important to take in a lot of good quality hydrogen into the body. As we live in stressful times, the importance and demand for hydrogen are increasing. The habit of drinking freshly made hydrogen water will lead to a better quality of life.








■We adopt wireless charge type





It's easy to charge just by putting it on, so you don't have to worry about plugging and unplugging the charging cable, so you can use it comfortably.








■Product specifications































the main body
Name Lita hydrogen Dual Bottle
Dimensions 75×207mm
Weight about 230g
Capacity 330ml
Reduction method DC electrolysis method
Battery Lithium-ion battery
Battery capacity 3.7V / 1010mAh
















































Accessories
Name Qi wireless charging stand
Charging terminal Qi standard
Dimensions 98×11.3mm
Weight 65g
Name AC power supply(AC100-240V 50Hz/60Hz)
Output DC5V/2A
Weight 50g
Name Micro USB cord
Dimensions 1.2m
Name Replacement packing


(1 each for cap and base)
























Dedicated inhalation kit body
Name Nasal cannula with inhalation tube
Dimensions 2.1m
Weight about 50g
Material PVC






















Suction tube connection kit
Dimensions 3.2×43.29mm
Weight about 10g
Material silicon
























Dedicated inhalation kit accessories
Name Inhalation kit storage pouch
Dimensions 150×50×100mm
Weight about 50g
Material nylon



















■Charging method





When using for the first time, please use it after fully charging.


*The remaining charge of the initial battery varies depending on the status at the time of shipment.




  1. Connect the included AC power supply and Micro USB cord.


  2. Connect the Micro USB cord to the Qi wireless charging stand.


  3. Plug the AC power supply into a household outlet (AC100V).


    *Use a transformer if necessary.



  4. Place the main unit on the Qi wireless charging stand to charge.







Starting and completing charging



At the start of forward transmission, the power switch flashes blue.


When charging is complete, the power switch changes from blinking blue to lighting.


* Estimated charging time:about 180 minutes


(It may take longer than the estimated time due to charging with octopus wiring and deterioration of the lithium-ion battery. )


* When the battery runs out, the power switch will turn red and the power will automatically stop.








■How to use







  1. Fill the bottle with drinking water.


    *Do not use beverages other than water.



  2. Tighten the cap and lightly shake the main unit up and down to check for water leakage.


    *Be sure to check for water leaks every time.



  3. Open the lid of the cap and press the power switch.


    ・A UV lamp for sterilization lights up for a moment at the start.


    ・While generating, the LED light changes to various colors.



  4. When the LED light turns off, the hydrogen water is complete.









Generate hydrogen in 3-minute mode





Press and hold the power switch for 2 seconds. (The power switch flashes blue. * The display will be the same as during charging.)



Generate hydrogen in 10 minutes mode.





Press and hold the power switch for 2 seconds twice. (the power switch lights up in blue.)



Power off





Press and hold the power switch for 3 seconds.



  • To stop hydrogen generation in the middle, press and hold the power switch for 3 seconds.


  • If the power switch light turns red, it means that the battery is out of charge. Please recharge.


  • If you press the power switch without water, it will flash red and automatically stop after 3 seconds.














■Important





  • Continuous use of the bottle with the lid closed may increase the air pressure and cause malfunction due to the structure of the bottle.


  • When hydrogen is generated immediately after delivery, the special filter is not familiar with the water, so the hydrogen and oxygen bubbles are difficult to see.


  • Hydrogen dissolved in water is invisible, so it is not a malfunction.


  • The visible bubbles are bubbles of oxygen and hydrogen, so they have nothing to do with the hydrogen concentration. By repeating the number of times of hydrogen generation, the special filter will become familiar and many visible bubbles will be generated.











■How to use the inhalation kit







  1. Remove the cap of this product and add water. (80% to 90%)


  2. After attaching the cap, open the lid of the cap.


  3. Confirm the position of the connection kit so that the junction of the nozzle and plug of the connection kit is on the front side of the cap of this product.


    *Attach the intake hole on the back side of the connection kit to the hole in the bottle cap so that it does not shift.


    *Firmly push the base of the nozzle evenly with your finger so that the connection kit does not come off.



  4. Firmly insert the nasal cannula with inhalation tube into the nozzle of the inhalation tube connection kit that has been connected to the bottle cap.


  5. Check the direction so that the rotation stopper of the nasal cannula is on the top, and attach the nostril insertion part to the nostril. Put the strap tubes on the left and right ears, and adjust the length by sliding the slide ring up and down at the throat or the back of the head.


  6. Press the power switch of this product.


    (Long press once for 3 minutes mode/Long press twice for 10 minutes mode.)





Hydrogen gas inhalation is recommended for 10 to 30 minutes. Do not inhale for more than 30 minutes at a time.





Please choose the inhalation method that suits you within the range of A to C.




  1. Generating hydrogen in 10 minutes mode and inhale hydrogen for 10 minutes simultaneously.


  2. After inhaling in A, inhale hydrogen for a total of 20 minutes while generating hydrogen in 10 minutes mode.


  3. After B, inhale for 10 minutes while hydrogen generation is stopped. Inhale hydrogen for a total of 30 minutes.














■Electrode cleaning method







  1. Remove the cap from the bottle.


  2. Put water (to the extent that the electrode is submerged) and detergent (citric acid) in the bottle, shake until there are no solids, and let it soak for about 10 hours.


  3. Thoroughly wash the electrode plates and bottles with water.


  4. After cleaning, assemble and complete. Align the stereotaxic point and connect the cap and base tightly. (Be sure to check that there are no water leaks.)


    * Please wash with citric acid once a month as a guide.










■Precautions when replacing/cleaning packing





If the packing is in a different position, it may cause water leakage. After replacing or cleaning the packing, pay attention to the top and bottom of the packing to properly attach the packing and screw cover.








■Inhalation kit Daily care







  1. ①The part that is directly attached to the nose is especially difficult to collect dirt, so please wipe it frequently with an alcohol disinfectant wet tissue, etc., and if you are concerned about dirt, wash it with water.


  2. ②After washing with water, dry thoroughly in a shaded and well-ventilated place.

    *If there is obvious deterioration such as discoloration or scratches, replace it with a new one.













■For safe use





It's important. For your safety, please be sure to follow these instructions.


The following items must be observed in order to use this product correctly and to prevent harm to the user and others, as well as damage to property.





●The degree of danger and damage caused by improper handling is categorized and explained.


■PROHIBITION:Indicates a potential risk that could result in death, serious injury, or serious property damage. Never do this.


■WARNING: Indicates a potential risk that could result in serious injury or serious property damage.


■CAUTION:Indicates a potential risk that may result in minor injury or minor property damage.










■PROHIBITION







  • Do not put this product in a dish dryer, dishwasher, or cooking utensil. Fire, failure, electric shock, burns, deformation, and damage may also result.


  • If you are allergic to metals, go to the hospital, have a chronic disease, are pregnant, have a weak constitution, or have any other symptoms, be sure to consult your doctor before using this product.




Precautions when inhaling hydrogen gas





  • Continuous use of hydrogen gas inhalation is prohibited. Up to twice a day (use for 30 minutes each time) is the upper limit, and when using multiple times, be sure to open your interval for at least 6 hours before using.


  • When inhaling hydrogen gas, fire is strictly prohibited because hydrogen gas is generated. Never use a fire such as a cigarette while inhaling hydrogen, as it is dangerous within 1m of the place where it is being used.


  • If you feel sick while inhaling hydrogen gas, stop using it immediately.











■WARNING







  • If you have restricted water intake, be sure to consult a doctor before using.


  • If you put drinking water in this product and continuously generate hydrogen, the pressure inside the bottle will rise due to electrolysis, which may cause explosion or water leakage. Be sure to open the cap when generating hydrogen.


  • Do not store the hydrogen water produced by this product for a long time and drink it as soon as possible.


  • If you re-generate hydrogen water that you have not finished drinking, the pressure inside the bottle will increase, which may cause it to explode or leak.


  • Do not use in hot places such as places exposed to fire, direct sunlight, and inside a car under the hot sun. Do not store or leave it. Doing so may cause fire, rupture, or heat generation.


  • When charging, be sure to wipe off the water and do it in a place where it is not splashed with water. There is a risk of electric shock, short circuit, or fire.


  • If there is dust on the AC power plug, wipe it off before use. Also, do not connect or disconnect the AC power supply or Micro USB cord with wet hands.


  • Keep out of reach of infants. There is a risk of accident or trouble due to accidental ingestion of parts, etc. Also, do not lick the metal parts.


  • Never disassemble or modify this product.


  • This product uses a lithium-ion battery. When disposing of this product, be sure to dispose of it according to local instructions, as the battery may cause a fire or explosion.






Warnings when inhaling hydrogen gas





  • If a minor uses hydrogen gas inhalation, a parent or guardian should carefully read the precautions and use it with the child. For infants and the elderly, please use it carefully by getting used to it little by little from about 5 minutes.











■CAUTION







  • Do not dry or wash at temperatures above 60 degrees. Doing so may cause deformation or damage.


  • Do not use anything other than the included AC power supply. Failure to do so may cause malfunction.


  • Do not put water in this product and freeze it, or put hot water of 60 degrees or more. Doing so may cause rupture or damage.


  • Do not use any beverages other than water. Doing so may cause discoloration, odor, or malfunction.


  • When generating hydrogen, do not tilt this product sideways, but stand it upright on a flat surface.


  • When cleaning this product, never use a metal brush or abrasive.


  • When cleaning the electrode part, wash it without rubbing it strongly.


    *If calcium contained in tap water (white solid matter) adheres, please wash it with commercially available citric acid.


  • This product is designed to be used at 100 to 240V, but it is designed and manufactured for Japan. Please note that we will not be held responsible for any problems such as failure due to use overseas.


  • When carrying this product, make sure that the cap, bottle, and base are tightly closed.


  • Do not use alcohol or benzene-based organic solvents for cleaning.






Precautions when inhaling hydrogen





  • Do not store the cannula in a bent state. Doing so may cause deformation or damage, making it impossible to inhale hydrogen gas.


  • Make sure there are no cracks or condensation on the cannula before using the inhalation kit.


  • Wipe and clean the cannula as needed. Use running water when cleaning.


  • After cleaning the inhalation kit, do not dry it in the hot air of the hairdryer, in front of the stove, or in direct sunlight. Doing so may cause deformation or damage.


  • When inhaling hydrogen gas, please refrain from using it when it is difficult to breathe, such as when you have a stuffy nose or are sleeping.


  • For hygiene reasons, do not share with family members or others.